THE FURUKAWA BATTERY CO., LTD.





Start of page

Type list

Lead-acid storage battery

Stationary lead-acid storage battery

Series name Method Battery type Features Capacity range Expected life (Approx.) Major application
Vent type
(Catalyst plug
vent type)
Lead Standard 15 to 2400Ah 10 to 14 years Communication
Switching equipments
Electric power equipment operation
All other floating charge system
Vent type
(Catalyst plug
vent type)
Lead High-rate discharging 30 to 2500Ah 5 to 7 years UPS (Large and
Medium capacity)
Engine starting
Instrumentation
All other floating charge system
Vent type
(Catalyst plug
vent type)
Lead Standard 190 to 1980Ah 7 to 12 years Communication
Equipment operation
All other floating charge system

Valve-regulated stationary lead-acid battery

Series name Method Battery type Features Capacity range Expected life (Approx.) Major application
Valve regulated type Lead Standard 30 to 100Ah 5 to 7 years(Note) Communication
Switching equipments
Emergency lighting
Automatic control
All other floating charge system
Valve regulated type Lead Standard 50 to 3000Ah 7 to 9 years(Note) Communication
Switching equipments
Electric power equipment operation
All other floating charge system
Valve regulated type Lead Long life 50 to 3000Ah 13 to 15 years(Note) Communication
Switching equipments
Electric power equipment operation
All other floating charge system
Valve regulated type Lead Long life
Space saving
500 to 3000Ah 13 to 15 years(Note) Communication
Switching equipments
Electric power equipment operation
All other floating charge system
Valve regulated type Lead High-rate discharging 50,200,300Ah 7 to 9 years(Note) UPS
Mono-block
Space saving
100, 150Ah

(Note) Float life (Trickle life) evaluation temperature/ discharge current:
MSE・FVL・FMU-S・HSE→25℃/0.1C10A
FVH→25℃/3.3C10A
Expected life varies depending on usage condition (such as temperature, discharge rate), and the numeric value is not guaranteed.
“Expected life” is a lifetime assuming certain conditions and maintenance management.
 Here, the “expected life” can be expected in the case of the ambient temperature is 25℃, suitable floating charge voltage and number of discharge is several times a year, therefore it does not guarantee the years in actual use.

Small sized valve regulated lead-acid batteries

Series name Method Battery type Features Capacity range Expected life (Approx.)(Note4) Major application
Valve regulated type Lead Standard 12V 2 to 38Ah,
6V 10Ah
3 years(Note1)
Approx. 200 times(Note3)
Standby use
  • Communication equipment
  • Emergency lighting equipment
  • FA equipments such as robots and control equipment
  • Fire protection equipment
  • CATV, Optical communication system equipment
  • PHS cell base station, Microcell base station
  • Disaster prevention & crime prevention system equipment

Cycle use
  • Street light
  • Clock
  • Sprinkler
  • Traffic sign, others
Valve regulated type Lead Long life 12V 0.8 to 17Ah 6 years(Note1)
Valve regulated type Lead Ultra-long life 12V 2 to 65Ah 13 years(Note1)
Valve regulated type Lead High-rate discharging
Long life
12V 5.5 to 8.8Ah 3 years(Note2) UPS and other use
12V 10 to 38Ah 5 years(Note2)

(Standby use)

(Note1)A trickle life in the case of 25℃ constant, obtained from a high temperature accelerated test. The capacity test: 0.25C20A, Life determination: 50% of the rated capacity (20HR)

(Note2) A trickle life in the case of 30℃ constant, obtained from a high temperature accelerated test. Capacity test: 3C20A, Life determination: 3min. of sustained period.

Here, C20 shows a numeric value of 20 hrs rated capacity.


(Cycle use)

(Note3)Test temperature: 25℃, Discharge: 0.25C20A, Discharge stop voltage: 1.7V/cell, Charge: 2.45 V/cell constant voltage charge, Charge amount: 110%, Life determination: 50% of rated capacity (20HR), Cycle life of all the m series, FML series and FHL series are the same. Note that FPX series is incompatible with the cycle use.

Here, C20 shows a numeric value of 20 hrs rated capacity.

(Note4) “Expected life” is a life assuming certain conditions and maintenance management. The battery life in actual use varies with usage conditions (such as ambient temperature, discharge frequency, discharge rate and charge condition) and use history. Therefore the “expected life” does not guarantee the years of actual use.

Valve regulated lead-acid battery for cycle-use

Series name Method Battery type Features Capacity range Expected life25℃, DOD70%(Approx.) Major application
FCP Valve regulated type Lead Cycle use 500,1000Ah 3000 cycles(Note)
  • Renewable energy sector
  • Wind power/ Solar power generation
  • Peak shift, load leveling
  • Repetitive charge and discharge application
  • Others
UB Valve regulated type Lead Cycle use 1000Ah 4000 cycles(Note)
  • Renewable energy sector
  • Wind power/ Solar power generation
  • Peak shift, load leveling
  • Electric power regeneration application
  • Repetitive large current charge and discharge application
  • Others

(Note) “Expected life” is based on our recommended condition of use, and is different from a guaranteed value.

Alkaline storage battery

Stationary alkaline storage battery

Series name Method Battery type Features Capacity range Expected life (Approx.) Major application
Seal type Alkaline
sintered
Ultra-high-rate discharging 10 to 400Ah 12 to 15 years Equipment operation
Instrumentation
Control
Emergency lighting
Liquid type Alkaline
sintered
Ultra-high-rate discharging 20 to 1000Ah 12 to 15 years UPS
Engine starting
Emergency lighting
Equipment operation
Liquid type Alkaline
sintered
High-rate discharging 20 to 1200Ah 12 to 15 years UPS
Equipment operation
Instrumentation
Control
Emergency lighting
Liquid type Alkaline
pocket
Ultra-high-rate discharging 20 to 450Ah 12 to 15 years UPS
Engine starting
Emergency lighting
Equipment operation
Liquid type Alkaline
pocket
High-rate discharging 20 to 700Ah 12 to 15 years UPS
Equipment operation
Instrumentation
Control
Emergency lighting
Liquid type Alkaline
pocket
Intermediate of the High rate and standard discharge 20 to 1000Ah 12 to 15 years Emergency lighting
Operation
Instrumentation
Control
Liquid type Alkaline
pocket
Standard discharge 20 to 1000Ah 12 to 15 years Emergency lighting
Operation
Communication
Instrumentation
Control

Nickel-cadmium storage battery

Series name Method Battery type Features Capacity range Expected life Major application
Seal type Alkali High durability 100 to 10,000mAh Depends on use Disaster prevention equipment
Business equipment
Measuring equipment
Others

Battery Condition Watcher BCW

Battery Condition Watcher (BCW) is installed in the vicinity of the storage battery, and measures voltage, internal resistance and temperature of individual battery. The measured data are obtained by a system controller (BCWT4) through the wireless communication between BCWHub. Two Hubs can be connected to one BCWT4 and 128 BCWs can be connected in maximum. In the case of the more BCWs are necessary, this combination is added more.